BNPMX - DIAMAX POWDER 19112

  • MSDS: BNPMX
  • Manufacturer: EUTECTIC CORP
  • Product Name: DIAMAX POWDER 19112
  • National Stock Number: 3439-00-245-0810
Product Identification

Product ID:DIAMAX POWDER 19112
MSDS Date:05/01/1986
FSC:3439
NIIN:00-245-0810
MSDS Number: BNPMX

Responsible Party
EUTECTIC CORP
40-40 172ND ST
FLUSHING, NY 11358-9981
US

Emergency Phone: 718-358-4000

Info Phone: 718-358-4000; 312-932-1210

Cage: 72271

Contractor
EUTECTIC CORP
CHARLOTTE, NC 28273 US

Telephone: 704-527-9800/ 800-221-1433

Cage: 72271

Ingredients

NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


TUNGSTEN CARBIDE; (TUNGSTEN)

CAS: 12070-12-1

RTECS: YO7250000

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3


CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


IRON

CAS: 7439-89-6

RTECS: NO4565500

OSHA PEL 10 MG/M3 TDUST

ACGIH TLV: 5 MG/M3 FUME


SILICON

CAS: 7440-21-3

RTECS: VW0400000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


BORON

CAS: 7440-42-8

RTECS: ED7350000

OSHA PEL 10 MG/M3 TDUST

ACGIH TLV: 10 MG/M3


15 MG/M3 TDUST;5 MG/M3 RDUST.

CAS: 7429-90-5

RTECS: BD0330000

OSHA PEL SEE INGREDIENT NAME

ACGIH TLV: 10 MG/M3 DUST


OVEREXP TO AMORPHOUS SILICA CAN

RTECS: 9999999ZZ


CHROMATE PRODUCTION WORKERS EXPOSED TO CR VI CMPDS

RTECS: 9999999ZZ


THRU SKIN CAN CAUSE SYSTEMIC POISONING PRIMARILY

RTECS: 9999999ZZ


LONG TERM OVEREXP MAY CAUSE

RTECS: 9999999ZZ


WORKERS INDICATED HIGHER INCIDENCE OF LUNG & NASAL

RTECS: 9999999ZZ


FCSHLD W/FILTER LENS. PROVIDE PROT SCREENS &

RTECS: 9999999ZZ


THAT IS TO DARK TO SEE WORK ZONE; THEN GO TO NEXT

RTECS: 9999999ZZ


PROTECTORS, APRONS, HATS, SHOULDER

RTECS: 9999999ZZ


EYEWASH & DELUGE SHOWER .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:THERMAL SPRAYING MAY CREATE 1 OR MORE
OF FOLLOWING HLTH HAZ. FUMES, GASES & DUSTS CAN BE DANGEROUS TO
YOUR HLTH. ACUTE:OVEREXP TO FUMES, GASES & DUSTS MAY RSLT IN
DISCOMFORT SUCH AS DIZZ, NAUS OR DRYN ESS/IRRIT OF
NOSE/THROAT/EYES. ING 5:POSS EYE IRRIT. ING 3:INHAL OF FUME CAN
CAUSE IRRIT OF RESP SYS, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CHROMIUM:GROUP 1(IARC); GROUP 1(NTP).
NICKEL:GROUP 1(IARC); GROUP 2(NTP).
Effects of Overexposure:HLTH HAZ:DMG TO LUNGS & ASTHMA LIKE SYMPS.
SWALLOWING SALTS CAN CAUSE SEV INJURY/DEATH. DUSTS ON SKIN CAN FORM
ULCERS. EYES MAY BE BURNED. ALLERGIC RXNS LIKELY IN SOME PEOPLE.
ING 1:METALLIC TASTE, NA US, TIGHTNESS IN CHEST, FEVER,
ALLERGICRXNS. ALLERGIC RXN LIKELY IN ABOUT 10% OF WORKERS.
CHRONIC:OVEREXP TO (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:REMOVE TO WELL-VENTILATED AREA. CALL FOR MEDICAL AID. EMPLY
FIRST AID TECHNIQUES RECOMMENDED BY AMERICAN RED CROSS.
INHAL:REMOVE FROM OVEREXPOSURE. APPLY ARTIFICIAL RESPIRATION.
SKIN:WASH W/SOAP & WAT ER. EYES:REMOVE BY IRRIGATING
W/COPIOUSAMOUNTS OF WATER FOR AT LEAST 15 MINUTES. INGEST:CALL MD
IMMEDIATELY .

Fire Fighting

Flash Point:NONFLAMMABLE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONFLAMM UNDER NORMAL WORKING CNDTNS.
METAL PWDR DUST MAY PRESENT FIRE/EXPLO HAZ UNDER FAVORABLE CNDTNS
OF PARTICLE SIZE, DISPERSION & STRONG IGNITION SOURCE.

Accidental Release

Spill Release Procedures:CLEAN-UP BY VACUUMING, WET DUSTMOP/WET
CLEAN-UP. AVOID DUST GENERATION. USE APPROP FILTER W/VACUUM EQUIP
TO PREVENT AIRBORNE DUST LEVELS WHICH EXCEED PEL/TLV. IF AIRBORNE
DUST IS GENERATED, USE APPROP NIOSH/MSHA APPRVD RESP DURING
CLEAN-UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:MAINTAIN EXPOSURE BELOW GIVEN PEL/TLV.
USE INDUSTRIAL HYGIENE MONITORING TO ENSURE THAT USE OF PROD DOES
NOT CREATE EXPOS EXCEEDING PEL/TLV.
Other Precautions:REFER TO GIVEN REFERENCES FOR ADDITIONAL INFORMATION.
READ & UNDERSTAND MFR'S INSTRUCTIONS & PRECAUTIONARY LABEL ON PROD.
TRAIN WORKER TO KEEP HIS HEAD OUT OF FUMES, GASES & DUSTS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRABLE FUME
RESPIRATOR OR NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR WHEN
WORKING IN CONFINED SPACE/WHERE LOCAL EXHAUST/VENT DOES NOT KEEP
EXPOSURE BELOW RECOMMENDED EXPOS URE LIMIT.
Ventilation:USE ENOUGH GENERAL VENT & LOCAL EXHAUST AT WORK SITE TO
KEEP FUMES, GASES & DUSTS FROM WORKER'S BRTHG ZONE & GEN AREA.
Protective Gloves:WELDER'S GLOVES.
Eye Protection:CHEM WORK GOGG & WEAR HELMET/USE(ING 13)
Other Protective Equipment:WEAR HAND, HEAD & BODY PROT WHICH HELP TO
PREVENT INJURY FROM RADIA & FLAMES. SEE ANSI Z49.1. THIS MAY INCL
ARM (ING 15)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:METAL & COATING, ETC. REAS EXPECTED CONSTITUENTS OF
FUME WOULD INCL COMPLEX OXIDES OF METALS LISTED IN INGS. GASEOUS
RXN PRODS MAY INCL CO & CO*2. OZONE & NITROGEN OXIDES MAY BE FORMED
BY RADIA. EFTS OF OVEREXP:FUMES, GASES& DUSTS MAY LEAD TO
SIDEROSIS (IRON DEPOSITS IN LUNGS) & MAY AFFECT (ING 8)

Chemical Properties

Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:DECOMP PRODS OF NORMAL OPERATION INCL
THOSE ORIGINATING FROM VOLAT, RXN/OXIDATION OF INGS, PLUS THOSE
FROM BASE (SUPDAT)

Disposal

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSABLE CONTAINER OR
LINER IN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE
W/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.